Rittals RiMatrix S – Impressions of The Standardized Data Centres

Rittals RiMatrix S – Impressions of The Standardized Data Centre

Rittals RiMatrix S - Impressions of The Standardized Data CentreWe just finished a successful display of Rittals, RiMatrix S at the South Court hotel in Raheen last week. The event was part of a wider roadshow to show off the latest innovation from the German companies IT Infrastructure division.

Rittals RiMatrix S - Impressions of The Standardized Data Centre
The front facing racks for the servers. Note the KVM allowing easy access to the equipped DCIM software.

The single six model on display came on the back of an articulated lorry in an open designed container to demonstrate how its standardised concept can be adapted to both internal and external usage. The concept was to reduce the cost and time needed to create a fully featured data center that allowed for scalability and portability if needed.
The RiMatrix S is the Germans one-part standardised datacentre. It’s just one product code. The RiMatrix comes as a module with defined interfaces for power, cooling and monitoring, dimensions and functions. This considerably reduces the amount of planning work required. It has a guaranteed PUE of up to 1.15.

Rittals RiMatrix S - Impressions of The Standardized Data Centre
RiMatrix S rear of the TSIT racks

The Space-saving climate control in the raised floor  allows air routing with high energy efficiency, allowing n+1 redundancy in climate control.The heat exchangers are located beneath the racks.The heat exchanger connection is easily accessible via the raised floor behind the racks.

Rittals RiMatrix S - Impressions of The Standardized Data Centre
Door dividing the PSU and Server Racks

The Rimatrix S also comes with the CMC monitoring system giving users real time information on temp, humidity, leakage etc. This can be added to by Rizone, Rittals DCIM software to give  monitoring and evaluation of operating states.

Rittals RiMatrix S - Impressions of The Standardized Data Centre
Under the false floor with a clear view of the piping connecting to the cooler

This was a very impressive display and a solution and those who saw it could see its practical benefits in reducing the planning, implementation and build time. The turnkey solution  with a standardised dimensions can be used in so many different scenarios.
If you have any questions or if you want some more information about Rittals RiMatris S then give us a call at 1800 911 000.